Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Health ; (6): 137-140, 2023.
Article in Chinese | WPRIM | ID: wpr-973166

ABSTRACT

@#<b>Objective</b> To complete the Monte Carlo design and preliminary test of X-ray protective rubber. <b>Methods</b> According to the characteristics of X-ray energy spectrum for interventional therapy, the shielding effects of lead rubber, tungsten and bismuth composite rubber, and gadolinium and bismuth composite rubber samples were calculated by Monte Carlo simulation. The variation law of lead equivalent of lead-free rubber and lead rubber with X-ray peak tube voltage was obtained through actual measurement. <b>Results</b> Within the peak tube voltage range of 60-110 kV, lead-free rubber effectively replaced lead rubber. <b>Conclusion</b> The shielding and attenuation effect of the existing lead-free protective rubber on low-energy stray X-rays is better than that of lead rubber. Considering the inherent defects of lead rubber, flexible X-ray protective materials with thermoplastic elastomer as filler will have broad development prospects.

2.
Chinese Medical Equipment Journal ; (6): 19-23, 2018.
Article in Chinese | WPRIM | ID: wpr-700056

ABSTRACT

Object To develop an easy-assembled and-disassembled image diagnostic module to solve the problems of the tent-form field medical system in size, weight, mobility, accessories, protection and etc, which is of high references for combination and integration scheme of large-scale digital imaging equipment by adopting box instrumentation.Methods The module had its design executed with system modeling, structure simulation and CAD after its service requirements were analyzed. The design fell into the ones for overall framework, combination mode, packaging and buffer vibration isolation, ergonomics, box instrumentation, radiography accessories for vertical and horizontal positions, protection device and etc.Results The module was gifted with radiodiagnosis-related performances such as digital radiography, digital diagnosis,diagnosis reporting, compatibility to vertical- and horizontal- position radiography, and radiation protection during war conditions.Conclusion The module developed gains advantages in power, continuous radiography, assembling and disassembling, accessories and protection, and thus meets the requirements of the tent-form field medical system in mass casualties imaging diagnosis.

3.
Chinese Medical Equipment Journal ; (6): 10-14, 2018.
Article in Chinese | WPRIM | ID: wpr-700054

ABSTRACT

Object To study on the X-ray protection module in the radiodiagnosis unit to protect X-ray technicians, other medical staffs and etc against radiation during standing and lying X-ray examinations in the tent-form field medical system.Methods A local tightness protection solution was put forward involving in lead protective materials, standing shoot rack,diagnosis couch as well as considerations on the service orientation of the tent-form field medical system and the operation mode of the X-ray tent. A protective support with fast-plug and lateral folding structure was designed based on X-ray radiation protection principle and lead equivalent calculation of the lead curtain. An X-ray protection module was developed with the lend curtain, protective support, warning sign and etc.Results The dose peaked at vertical direction, and at vertical direction the annual dose to the public 1 m away from the tent was 78.8μSv which was far lower than the limit value 1 mSv. The strength of the protective support met the requirements, and the maximum deformation of the support bar was 15 mm after the suspension of the lead curtain.Conclusion The X-ray protection module gains advantages in design, structure, operation,rapid deployment and withdrawal, handling and transport as well as protective effective according to GB 18871—2002 regulation, and thus can be used for X-ray diagnosis at peace and war time.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 423-425, 2009.
Article in Chinese | WPRIM | ID: wpr-393478

ABSTRACT

Objective To evaluate the value of the muhifunctional angle regulator with shields in skeletal fluorosis X-ray radiography.Methods Conventional radiography,regulator with shields and regulator for radiography were used to examine the forearms and shanks of 78 patients,and then the quality of the photos and the diagnostic results were compared.The dose rates on patients' foresides,sides,and bottoms of division 1 and 2 m were measured by pressure ionization instrument.Results Regulator with shields and regulator for radiography had a higher rate of good quality than conventional radiography by 39 %,and consequently the diagnostic accuracy rate were improved by 37%(X2 = 43.33,43.98 and 17.76,14.56,P < 0.01).By conventional radiography the average dose rates on forearms and shanks I and 2 m away from X-ray axis were 1198,934 and 1439,1175 μSv/h,respectively;while regulator with shields and single regulator were used,corresponding average dose rates were 80.6,39.4 and 95.6,59.5/JSv/h and 375.7,187 and 447,226.3 μSv/h,respectively.Conclusions Angle regulator with shields is effective devices to examine the forearms and shanks of the patients who are suffering from dysfunction of skeletal fluorosis.

SELECTION OF CITATIONS
SEARCH DETAIL